管道磨损损失简易表总汇
|
|
发布日期:[2015-09-15] 共阅[1437]次 |
管道磨损损失简易表总汇
管径(mm) | 25 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 180 | 200 | 250 | 300 | 流量(L/S) | 1 | 32.7 | 3.5 | 0.8 |
|
|
|
|
|
|
|
|
| 2 | 13.0 | 1.4 | 3.1 | 0.8 | 0.4 |
|
|
|
|
|
|
| 4 |
| 55 | 13 | 3.2 | 1.6 | 0.4 |
|
|
|
|
|
| 6 |
|
| 29 | 7.1 | 3.3 | 0.8 | 0.23 |
|
|
|
|
| 8 |
|
|
| 13 | 5.9 | 1.3 | 0.4 | 0.16 |
|
|
|
| 10 |
|
|
| 20 | 9.6 | 2.1 | 0.63 | 0.26 | 0.11 |
|
|
|
|
| 15 |
|
| 21.6 | 6.8 | 1.3 | 0.58 | 0.27 | 0.13 |
|
|
|
| 20 |
|
|
| 8.6 | 2.7 | 1.10 | 0.50 | 0.26 | 0.07 |
|
|
|
| 25 |
|
| 13 | 4.1 | 1.6 | 0.74 | 0.37 | 0.12 |
|
|
|
| 30 |
|
| 19.4 | 5.9 | 2.3 | 1.05 | 0.53 | 0.18 | 0.07 |
|
|
|
| 40 |
|
| 10.7 | 4.2 | 1.90 | 0.93 | 0.30 | 0.12 |
|
|
|
| 50 |
|
|
| 6.4 | 2.90 | 1.50 | 0.48 | 0.19 |
|
|
|
|
| 60 |
|
| 9.4 | 4.30 | 2.10 | 0.68 | 0.27 |
|
|
|
|
| 70 |
|
|
| 5.80 | 2.90 | 0.93 | 0.37 |
|
|
|
|
|
| 80 |
|
| 7.70 | 3.70 | 1.20 | 0.49 |
|
|
|
|
|
| 90 |
|
| 9.60 | 4.70 | 1.50 | 0.61 |
|
|
|
|
|
|
| 100 |
|
| 6.10 | 1.90 | 0.76 |
|
|
|
|
|
|
| 110 |
|
| 7.20 | 2.30 | 0.90 |
|
|
|
|
|
|
|
| 120 |
| 8.50 | 2.80 | 1.10 |
|
|
|
|
|
|
|
| 130 |
|
| 3.30 | 1.30 |
|
|
|
|
|
|
|
|
| 140 |
| 3.70 | 1.50 |
|
|
|
|
|
|
|
|
| 160 |
| 4.90 | 2.00 |
|
|
|
|
|
|
|
|
|
| 180 | 0.20 | 2.40 |
|
|
|
|
|
|
|
|
|
| 200 |
| 3.00 |
注:直管道摩擦损失简易表(约计)管 100mm直管损失米数以新铸铁管为标准,旧管加倍。 一定管路直径的zui大流量值及zui大流速值
管路直径(mm) | zui大流量(L/S) | zui大流速(m/S) | 管路直径(mm) | zui大流量(L/S) | zui大流速(m/S) | 25 | 1 | 2.04 | 125 | 30.0 | 2.14 | 32 | 2.5 | 1.69 | 150 | 43.0 | 2.45 | 50 | 4.17 | 2.12 | 180 | 60.0 | 2.49 | 65 | 6.67 | 2.01 | 200 | 83.0 | 2.69 | 80 | 10.0 | 2.26 | 250 | 133.3 | 2.72 | 100 | 18.4 | 2.33 | 300 | 192.0 | 2.71 |
注:超过此值管路损失显著增加。 阀及弯管折合直管长度(每台)
名称 | 折合管路直径倍数 | 备注 | 全开闸阀 | 13 | 未畅开加倍 | 标准弯管 | 25 |
| 逆止阀 | 100 |
| 底阀 | 100 | 部分堵塞加倍 |
注:例如 100mm直径管,底阀折合 100倍直径等于 100χ100=10000=10m直管长度,假定流量为 8L/S查(直管道摩擦损失简易表)、只管每 100m损失1.3m、则 10m损失 0.13m、即一台 100m底阀,流量为 8L/S时,则损失扬程 0.13m。 |
|
| |
|
|